• NERC Data Catalogue Service
  •  
  •  
  •  

Functionalisation data of a carbon electrode biosensor for detection of antimicrobial resistance

The dataset consists of results of the electrochemical circle fit of the Nyquist plot generated by NOVA software to measure the Charge Transfer Resistance (RCT). Data demonstrates the curve of real and imaginary resistance against charges transmitted in the media of the carbon electrode biosensor. The change in RCT can detect the presence of the targeted antimicrobial resistance (AMR) DNA. The experiments were conducted by immersing the sensor's electrode in different concentrations of the target AMR DNA to determine the limit of detection. Full details about this nonGeographicDataset can be found at https://doi.org/10.5285/6bc69e2a-c771-4538-832e-2f6824b63474

Simple

Date (Publication)
2022-01-12
Identifier
https://catalogue.ceh.ac.uk/id/6bc69e2a-c771-4538-832e-2f6824b63474
Identifier
doi: / 10.5285/6bc69e2a-c771-4538-832e-2f6824b63474
Other citation details
Mitrakos, V., Al Mshelesh, H., Bridle, H., Desmulliez, M. (2022). Functionalisation data of a carbon electrode biosensor for detection of antimicrobial resistance. NERC EDS Environmental Information Data Centre 10.5285/6bc69e2a-c771-4538-832e-2f6824b63474
Author
  Heriot-Watt University - Mitrakos, V.
Author
  Heriot-Watt University - Al Mshelesh, H.
Author
  Heriot-Watt University - Bridle, H.
https://orcid.org/0000-0001-9068-7624
Author
  Heriot Watt University - Desmulliez, M.
https://orcid.org/0000-0002-2441-1598
Point of contact
  Heriot-Watt University - Al Mshelesh, H.
Custodian
  NERC EDS Environmental Information Data Centre
Publisher
  NERC EDS Environmental Information Data Centre
Owner
  Heriot-Watt University
GEMET - INSPIRE themes, version 1.0
  • Environmental Monitoring Facilities
Access constraints
otherRestrictions Other restrictions
Other constraints
no limitations
Use constraints
otherRestrictions Other restrictions
Other constraints
This resource is available under the terms of the Open Government Licence
Use constraints
otherRestrictions Other restrictions
Other constraints
If you reuse this data, you should cite: Mitrakos, V., Al Mshelesh, H., Bridle, H., Desmulliez, M. (2022). Functionalisation data of a carbon electrode biosensor for detection of antimicrobial resistance. NERC EDS Environmental Information Data Centre https://doi.org/10.5285/6bc69e2a-c771-4538-832e-2f6824b63474
Metadata language
EnglishEnglish
Character set
utf8 UTF8
Topic category
  • Environment
Begin date
2021-07-15
End date
2021-07-29
Distribution format
  • JPEG ()

Distributor
  NERC EDS Environmental Information Data Centre
OnLine resource
Download the data

Download a copy of this data

OnLine resource
Supporting information

Supporting information available to assist in re-use of this dataset

Hierarchy level
nonGeographicDataset Non geographic dataset
Other
nonGeographicDataset

Conformance result

Date (Publication)
2010-12-08
Statement
The fabrication process involves multi LTCC layers, and screen printing of silver reference electrode (RE), carbon layer of working electrode (WE) and counter electrode (CE), and the dielectric layers. The SPCEs were functionalised with a specific (Peptide nucleic acid) PNA probe, by electrografting through in situ generated diazonium cations. Then creating a 4-carboxyphenyl (AP) film on the electrode surface after the modification of SPCEs electrochemical by reduction of the in situ generated 4-carboxyphenyl diazonium salt, using four cyclic voltammetry (CV) scans from +0.4 to -0.6 V at a scan rate of 100mV/s. The AP film then activated via 60 min incubation in 1-Ethyl-3-(3-Dimethylaminopropyl)Carbodiimide (EDC) and NHS (N-hydroxysuccinimide) in a MES (2-(Nmorpholino) EthaneSulfonic acid), PH 5.0. After, the electrode surface rinsed in MES buffer, and incubated it in amino-modified PNA probe dispersed in droplet of PBS buffer for 60 min at room temperature. Formation of a blocking film by droplet deposition to the electrode of 1% v/v ethanolamine/PBS buffer and incubated for 30 min in room temperature. Finaly, 52 min incubation with complimentary DNA target and electrochemical impedance spectroscopy (EIS) measurements by (Metrohm-Autolab, PGSTAT204/FRA32M), (dRCT 100kHz to 0.3Hz) in a 1mM KCl + 2mM Ferri/Ferrocyanide solution. DNA strand hybridizing to probs lead to an accumulation of negative charge on the electrode surface causing an increase in the charge transfer resistance (RCT).
File identifier
6bc69e2a-c771-4538-832e-2f6824b63474 XML
Metadata language
EnglishEnglish
Character set
ISO/IEC 8859-1 (also known as Latin 1) 8859 Part 1
Hierarchy level
nonGeographicDataset Non geographic dataset
Hierarchy level name
nonGeographicDataset
Date stamp
2025-11-05T08:31:10
Metadata standard name
UK GEMINI
Metadata standard version
2.3
Point of contact
  NERC EDS Environmental Information Data Centre
Lancaster Environment Centre, Library Avenue, Bailrigg , Lancaster , LA1 4AP , UK
https://eidc.ac.uk/
 
 

Overviews

Spatial extent

Keywords

GEMET - INSPIRE themes, version 1.0
Environmental Monitoring Facilities

Provided by

logo

Share on social sites

Access to the portal
Read here the full details and access to the data.

Associated resources

Not available


  •  
  •  
  •