Photosynthetic-CO2 response curves at different leaf temperatures in tropical montane rainforest tree species from Colombian Andes, 2022
This dataset contains information about temperature response curves of ACi (i.e., CO2 response curves of net photosynthesis) that were collected on Colombian Andean forests tree species that were planted in three, common-garden tree plantations along a 2000m altitudinal gradient. Specifically, individuals of cold- and warm-affiliated species were planted under common soil and water conditions, exposing them to the hot and cold extremes of their thermal niches, respectively. This work was supported by the UK Natural Environment Research Council (NE/R001928/1) Full details about this dataset can be found at
https://doi.org/10.5285/cc4c656f-4e4d-4f26-af23-69b4f007e43f
Simple
- Date (Publication)
- 2024-02-20
- Identifier
- doi: / 10.5285/cc4c656f-4e4d-4f26-af23-69b4f007e43f
- Other citation details
- Dusenge, M.E., González-Caro, S., Restrepo, Z., Meir, P., Hartley, I.P., Sitch, S., Sanchez, A., Mercado, M.L. (2024). Photosynthetic-CO2 response curves at different leaf temperatures in tropical montane rainforest tree species from Colombian Andes, 2022. NERC EDS Environmental Information Data Centre 10.5285/cc4c656f-4e4d-4f26-af23-69b4f007e43f
- GEMET - INSPIRE themes, version 1.0
-
- Habitats and Biotopes
- GEMET - Concepts, version 4.1.3
- Keywords
-
- A-Ci curves
- thermal acclimation
- Colombian Andes
- tropical montane forests
- Access constraints
- otherRestrictions Other restrictions
- Other constraints
- no limitations
- Use constraints
- otherRestrictions Other restrictions
- Use constraints
- otherRestrictions Other restrictions
- Other constraints
- If you reuse this data, you should cite: Dusenge, M.E., González-Caro, S., Restrepo, Z., Meir, P., Hartley, I.P., Sitch, S., Sanchez, A., Mercado, M.L. (2024). Photosynthetic-CO2 response curves at different leaf temperatures in tropical montane rainforest tree species from Colombian Andes, 2022. NERC EDS Environmental Information Data Centre https://doi.org/10.5285/cc4c656f-4e4d-4f26-af23-69b4f007e43f
- Spatial representation type
- textTable Text, table
- Metadata language
- EnglishEnglish
- Character set
- utf8 UTF8
- Topic category
-
- Biota
- Begin date
- 2022-01-01
- End date
- 2022-03-31
N
S
E
W
- Unique resource identifier
- WGS 84
- Distribution format
-
-
Comma-separated values (CSV)
()
-
Comma-separated values (CSV)
()
- OnLine resource
-
Download the data
Download a copy of this data
- OnLine resource
-
Supporting information
Supporting information available to assist in re-use of this dataset
- Hierarchy level
- dataset Dataset
- Other
- dataset
Conformance result
- Date (Publication)
- 2010-12-08
- Statement
- Data collection protocol: in January – March 2022, Aci curves (i.e., CO2 response curves of net photosynthesis) were done at a pre-determined saturating light intensity of 1800 PAR (Qin in the database). Aci curves were done at different leaf temperature targets between 15 and 40 degree Celcius, with 5 degree celcius steps. Before starting any ACi curve, the leaf was allowed to acclimate at each temperature for at least 10 min and the ACi was initiated once both Anet and stomatal conductance were stable for at least 2 min. Throughout each Aci, the stability time at each CO2 reference concentration (410, 50, 100, 150, 250, 410, 800, 1200, 1600, and 2000 in this order) was set to 45 - 180 seconds, the automatic match was programmed before recording any data at each CO2 reference concentration. Measurements were taken with an LI6800 Portable Photosynthesis System under field conditions. LI6800 indicates whether there is a leak, but measurements were always done after ensuring there was no leak in the system, therefore, no subsequent leak correction was necessary. At the beginning of each measurement day, automatic warm-up test was run to detect any problem within the instrument, and only measurements were initiated when all errors have been fixed as suggested by the instrument system. The leaf temperature was derived from the thermocouple of the instrument.
- File identifier
- cc4c656f-4e4d-4f26-af23-69b4f007e43f XML
- Metadata language
- EnglishEnglish
- Character set
- ISO/IEC 8859-1 (also known as Latin 1) 8859 Part 1
- Hierarchy level
- dataset Dataset
- Hierarchy level name
- dataset
- Date stamp
- 2025-11-13T16:26:50
- Metadata standard name
- UK GEMINI
- Metadata standard version
- 2.3
Point of contact
NERC EDS Environmental Information Data Centre
Lancaster Environment Centre, Library Avenue, Bailrigg
,
Lancaster
,
LA1 4AP
,
UK
https://eidc.ac.uk/
Overviews
Spatial extent
N
S
E
W
Provided by
Associated resources
Not available
NERC Data Catalogue Service