Isotope compositions in a network of groundwater wells impaired by an underground blowout
During the drilling of an exploration well in the 1960s, an underground blowout occurred near Sleen, The Netherlands. During approximately 25 months, near-continuous leakage of large amounts of natural gas was released into the subsurface. After the blowout, the local drinking water production company installed a network of groundwater monitoring wells to monitor for possible adverse effects on groundwater quality at the blowout site. Today, more than 50 years after the blowout, the groundwater is still impaired. Data has been correlated with previously published data by Schout et al. (2018) covering description of geology and well depths. During two fieldtrips (November 2019 & October 2020) water samples were collected from several wells covering: - Bulk gas compositions (methane, ethane, propane, oxygen, nitrogen, CO2, Argon). Bulk isotope compositions of methane (δ13C & δH), carbon dioxide (δ13C) and nitrogen (δ15N). - Methane clumped isotope compositions (ΔCD & ΔDD). - Inorganic parameters (hydrocarbons, anions, cations, DOC, alkalinity, nitrate and ammonium). The dataset was created within SECURe project (Subsurface Evaluation of CCS and Unconventional Risks) -
https://www.securegeoenergy.eu/.
This project has received funding from the European Union’s Horizon 2020 research and innovation programme under grant agreement No 764531.
Simple
- Date (Creation)
- 2021-04-21
- Maintenance and update frequency
- notApplicable notApplicable
- GEMET - INSPIRE themes, version 1.0
- BGS Thesaurus of Geosciences
-
- Carbon dioxide
- Methane
- Isotopes
- NGDC Deposited Data
- UKCCS
- dataCentre
- Keywords
-
- NERC_DDC
- Access constraints
- otherRestrictions Other restrictions
- Other constraints
- licenceOGL
- Use constraints
- otherRestrictions Other restrictions
- Other constraints
- The copyright of materials derived from the British Geological Survey's work is vested in the Natural Environment Research Council [NERC]. No part of this work may be reproduced or transmitted in any form or by any means, or stored in a retrieval system of any nature, without the prior permission of the copyright holder, via the BGS Intellectual Property Rights Manager. Use by customers of information provided by the BGS, is at the customer's own risk. In view of the disparate sources of information at BGS's disposal, including such material donated to BGS, that BGS accepts in good faith as being accurate, the Natural Environment Research Council (NERC) gives no warranty, expressed or implied, as to the quality or accuracy of the information supplied, or to the information's suitability for any use. NERC/BGS accepts no liability whatever in respect of loss, damage, injury or other occurence however caused.
- Other constraints
- Available under the Open Government Licence subject to the following acknowledgement accompanying the reproduced NERC materials "Contains NERC materials ©NERC [year]"
- Spatial representation type
- textTable Text, table
- Metadata language
- EnglishEnglish
- Topic category
-
- Geoscientific information
- Geographic identifier
-
NETHERLANDS [id=202000]
- Date (Creation)
- 1979
- Geographic identifier
-
NL
- Date (Revision)
- 2009
- Geographic identifier
-
NLD
- Date (Revision)
- 2009
N
S
E
W
))
- Begin date
- 2019-10-29
- End date
- 2020-10-30
- Unique resource identifier
- WGS 84 (EPSG::4326)
- Distribution format
-
-
MS Excel
()
-
MS Excel
()
- OnLine resource
- Data
- OnLine resource
- Digital Object Identifier (DOI)
- Hierarchy level
- dataset Dataset
- Other
- dataset
Conformance result
- Date (Publication)
- 2011
- Explanation
- See the referenced specification
- Pass
- No
Conformance result
- Date (Publication)
- 2010-12-08
- Explanation
- See http://eur-lex.europa.eu/LexUriServ/LexUriServ.do?uri=OJ:L:2010:323:0011:0102:EN:PDF
- Pass
- No
- Statement
- Analysis of trace metal and major cations was conducted with inductively coupled plasma mass spectrometry (ICP-MS). Large volume (>30L) groundwater samples with dissolved methane gas were collected in pressurised cannisters. In the laboratory, cannisters were depressurised for methane degassing from the water. Headspace methane gas was collected in all metal cannisters for methane clumped isotope analyses. Seperate, small volume (~200ml) gas & water samples were collected in Isoflasks for bulk methane isotope analyses and inorganic parameters. Natural gas composition and bulk methane and CO2 isotope analyses were analysed a Agilent GC. Carbon isotopes of methane on an Agilent 6890N GC interfaced to a Thermo Delta S IRMS. Methane isotopes on an Agilent 7890A GC interfaced to a MAT 253 IRMS. Methane clumped isotope analyses are conducted on a Thermo Scientific IRMS-253 Ultra.
- File identifier
- c0f687e6-2217-1954-e054-002128a47908 XML
- Metadata language
- EnglishEnglish
- Hierarchy level
- dataset Dataset
- Date stamp
- 2025-05-07
- Metadata standard name
- UK GEMINI
- Metadata standard version
- 2.3
Point of contact
British Geological Survey
Environmental Science Centre,Keyworth
,
NOTTINGHAM
,
NOTTINGHAMSHIRE
,
NG12 5GG
,
United Kingdom
+44 115 936 3100
- Dataset URI
- http://data.bgs.ac.uk/id/dataHolding/13607744
Overviews

Spatial extent
N
S
E
W
))
Provided by

Associated resources
Not available