• NERC Data Catalogue Service
  •  
  •  
  •  

X-ray micro-tomography dataset of Ketton carbonate - Unsegmented (raw data)

The images in this dataset are a sample of Ketton carbonate from a micro-computed tomography (micro-CT) scan acquired with a voxel resolution of 4.52 µm. This dataset is part of a study on the effects of Voxel Resolution in a study of flow in porous media. A brief overview of this study summarised from Shah et al 2015 follows. A fundamental understanding of flow in porous media at the pore-scale is necessary to be able to upscale average displacement processes from core to reservoir scale. The study of fluid flow in porous media at the pore-scale consists of two key procedures: Imaging reconstruction of three-dimensional (3D) pore space images; and modelling such as with single and two-phase flow simulations with Lattice-Boltzmann (LB) or Pore-Network (PN) Modelling. Here we analyse pore-scale results to predict petrophysical properties such as porosity, single phase permeability and multi-phase properties at different length scales. The fundamental issue is to understand the image resolution dependency of transport properties, in order to up-scale the flow physics from pore to core scale.

Simple

Date (Creation)
2020-05-06
Identifier
http://data.bgs.ac.uk/id/dataHolding/13607714
Originator
  Imperial College London - Saurabh M Shah
London , United Kingdom
Distributor
  British Geological Survey - Enquiries
Point of contact
  British Geological Survey - Enquiries
Maintenance and update frequency
notApplicable notApplicable
GEMET - INSPIRE themes, version 1.0
  • Geology
BGS Thesaurus of Geosciences
  • NGDC Deposited Data
  • UKCCS
  • Carbonates
  • Carbon capture and storage
  • Tomography
dataCentre
  • UKCCS
  • NGDC Deposited Data
Keywords
  • NERC_DDC
Access constraints
otherRestrictions Other restrictions
Other constraints
licenceOGL
Other constraints
Available under the Open Government Licence subject to the following acknowledgement accompanying the reproduced NERC materials "Contains NERC materials ©NERC [year]"
Use constraints
otherRestrictions Other restrictions
Other constraints
The copyright of materials derived from the British Geological Survey's work is vested in the Natural Environment Research Council [NERC]. No part of this work may be reproduced or transmitted in any form or by any means, or stored in a retrieval system of any nature, without the prior permission of the copyright holder, via the BGS Intellectual Property Rights Manager. Use by customers of information provided by the BGS, is at the customer's own risk. In view of the disparate sources of information at BGS's disposal, including such material donated to BGS, that BGS accepts in good faith as being accurate, the Natural Environment Research Council (NERC) gives no warranty, expressed or implied, as to the quality or accuracy of the information supplied, or to the information's suitability for any use. NERC/BGS accepts no liability whatever in respect of loss, damage, injury or other occurence however caused.
Other constraints
Available under the Open Government Licence subject to the following acknowledgement accompanying the reproduced NERC materials "Contains NERC materials ©NERC [year]"
Metadata language
EnglishEnglish
Topic category
  • Geoscientific information
Begin date
2013-03-26
End date
2015-01-01

Reference System Information

No information provided.
Distribution format
  • Image (TIFF) ()

Distributor
  British Geological Survey - Enquiries
OnLine resource
Data ( WWW:DOWNLOAD-1.0-http--download )
OnLine resource
Data ( WWW:DOWNLOAD-1.0-http--download )
Hierarchy level
nonGeographicDataset Non geographic dataset
Other
non geographic dataset

Conformance result

Date (Publication)
2011
Explanation
See the referenced specification
Pass
No

Conformance result

Date (Publication)
2010-12-08
Explanation
See http://eur-lex.europa.eu/LexUriServ/LexUriServ.do?uri=OJ:L:2010:323:0011:0102:EN:PDF
Pass
No
Statement
Dry scans of small cylindrical Ketton carbonate core (5 mm diameter and 10 mm length) were scanned using a laboratory micro-CT scanner, a Versa XRM-500 X-Ray Microscope (Zeiss X-Ray Microscopy, Pleasanton, CA, USA). To study and analyse the effect of scaled voxel resolution on the pore-scale micro-CT images and corresponding transport properties, it was necessary to scan the sample with the same field of view with respect to change in voxel resolution. X-rays from a micro-focused X-ray source are used to look into the sample. The X-ray source produces a polychromatic X-ray beam and the projection data (3000 projections) were collected with a cone beam along the circular trajectory. The voltage was set at 80 kV and power at 7W. In our cone beam set-up, the voxel resolution is controlled by the proximity of the sample to the beam or X-ray source.
File identifier
bbb3db6a-a8c3-3c29-e054-002128a47908 XML
Metadata language
EnglishEnglish
Hierarchy level
nonGeographicDataset Non geographic dataset
Hierarchy level name
non geographic dataset
Date stamp
2025-12-11
Metadata standard name
UK GEMINI
Metadata standard version
2.3
Point of contact
  British Geological Survey
The Lyell Centre, Research Avenue South , EDINBURGH , LOTHIAN , EH14 4AP , United Kingdom
+44 131 667 1000
Dataset URI
http://data.bgs.ac.uk/id/dataHolding/13607714
 
 

Overviews

overview

Spatial extent

Keywords


Provided by

logo

Share on social sites

Access to the portal
Read here the full details and access to the data.

Associated resources

Not available


  •  
  •  
  •