[This dataset is embargoed until March 31, 2024]. This dataset is in vitro validation of a potassium sensor that will be inserted into a plant stem. The dataset shows the sensitivity and selectivity of the fabricated potassium sensor. The data was obtained by measuring changes in electrical current with an increase in concentrations of the primary ion (K+) and interfering ion (Na+) to extract the sensitivity and selectivity, respectively using a semiconductor parameter analyser. K+ ion sensing data, measured directly inside a plant stem, are absent as the in vivo experiment should be optimised further. Full details about this dataset can be found at
https://doi.org/10.5285/89998967-a974-4136-b650-b9af9f9d6969
Default
Identification info
- Metadata Language
- English (en)
- Character set
- utf8
- Dataset Reference Date ()
- 2023-07-26
- Identifier
- doi: / 10.5285/89998967-a974-4136-b650-b9af9f9d6969
- Other citation details
- Han, S., Malliaras, G.G. (2023). Phytoelectronic potassium sensor performance data. NERC EDS Environmental Information Data Centre 10.5285/89998967-a974-4136-b650-b9af9f9d6969
- Keywords
-
- Ion sensors
- Implantable sensors
- sensor validation
- Limitations on Public Access
- otherRestrictions
- Other constraints
- no limitations
- Use constraints
- otherRestrictions
- Use constraints
- otherRestrictions
- Other constraints
- If you reuse this data, you should cite: Han, S., Malliaras, G.G. (2023). Phytoelectronic potassium sensor performance data. NERC EDS Environmental Information Data Centre https://doi.org/10.5285/89998967-a974-4136-b650-b9af9f9d6969
- Spatial representation type
- textTable
- Topic category
-
- Biota
N
S
E
W
))
Distribution Information
- Data format
-
-
Comma-separated values (CSV)
()
-
Comma-separated values (CSV)
()
- Quality Scope
- dataset
- Other
- dataset
Report
- Dataset Reference Date ()
- 2010-12-08
- Statement
- The data were generated by measuring electrical current with an increase in ion concentrations stepwise using a semiconductor parameter analyser. There are raw data without data treatment. The applied voltage was 0 V and -0.6 V at the gate and drain terminal, respectively. Recorded output signal was drain current with the unit of ampere. This dataset was recorded in real time. Additionally, for in vitro validation, an artificial sap (Na+ 15 mM, Ca2+ 10 mM, Mg2+ 15 mM) was used with varying a K+ ion concentration.
Metadata
- File identifier
- 89998967-a974-4136-b650-b9af9f9d6969 XML
- Metadata Language
- English (en)
- Character set
- ISO/IEC 8859-1 (also known as Latin 1)
- Resource type
- dataset
- Hierarchy level name
- dataset
- Metadata Date
- 2023-07-26T15:55:04
- Metadata standard name
- UK GEMINI
- Metadata standard version
- 2.3
Environmental Information Data Centre
Lancaster Environment Centre, Library Avenue, Bailrigg
,
Lancaster
,
LA1 4AP
,
UK